Crystalline Silica Exposure Control Methods

According to OSHA’s Final Rule to Protect Workers from Exposure to Respirable Crystalline Silica, employers shall fully and properly implement the engineering and work practice control methods detailed in the table below based on the equipment used for the construction job. This data in this table, as well as more information on OSHA regulations, can be found in OSHA’s Small Entity Compliance Guide for the Respirable Crystalline Silica Standard for Construction (PDF). These recommendations apply to all occupational exposured to silica dust in construction work above 25 micrograms per cubic meter of air in an 8-hour work shift.

For more information about the silica dust regulations implemented by OSHA, please give us a call at 866-983-6427.

For a full list of silica dust collection tools, please take a look at our selection.

Engineering and Work Practice Control Methods

Use saw equipped with integrated water delivery system that continuously feeds water to the blade.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use saw equipped with integrated water delivery system that continuously feeds water to the blade.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

 

When Used Outdoors:

≤ 4 hours /shift: None

> 4 hours /shift: APF 10

 

When used indoors or in an enclosed area:

≤ 4 hours /shift: APF 10

> 4 hours /shift: APF 10

Engineering and Work Practice Control Methods

For tasks performed outdoors only:

Use saw equipped with commercially available dust collection system.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

Dust collector must provide the air flow recommended by the tool manufacturer, or greater, and have a filter with 99% or greater efficiency.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use saw equipped with integrated water delivery system that continuously feeds water to the blade.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

 

When Used Outdoors:

≤ 4 hours /shift: None

> 4 hours /shift: None

 

When used indoors or in an enclosed area:

≤ 4 hours /shift: APF 10

> 4 hours /shift: APF 10

Engineering and Work Practice Control Methods

For tasks performed outdoors only:

Use saw equipped with integrated water delivery system that continuously feeds water to the blade.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use tool equipped with integrated water delivery system that supplies water to cutting surface.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use drill equipped with commercially available shroud or cowling with dust collection system.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

Dust collector must provide the air flow recommended by the tool manufacturer, or greater, and have a filter with 99% or greater efficiency and a filter-cleaning mechanism.

Use a HEPA-filtered vacuum when cleaning holes.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

For tasks performed outdoors only:

Use shroud around drill bit with a dust collection system. Dust collector must have a filter with 99% or greater efficiency and a filter-cleaning mechanism.

Use a HEPA-filtered vacuum when cleaning holes.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: APF 10

> 4 hours /shift: APF 10

Engineering and Work Practice Control Methods

Use dust collection system with close capture hood or shroud around drill bit with a low-flow water spray to wet the dust at the discharge point from the dust collector.

OR

Operate from within an enclosed cab and use water for dust suppression on drill bit.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use tool with water delivery system that supplies a continuous stream or spray of water at the point of impact.

OR

Use tool equipped with a commercially available shroud and dust collection system.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

Dust collector must provide the air flow recommended by the tool manufacturer, or greater, and have a filter with 99% or greater efficiency and a filter-cleaning mechanism.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

 

When Used Outdoors:

≤ 4 hours /shift: None

> 4 hours /shift: APF 10

 

When used indoors or in an enclosed area:

≤ 4 hours /shift: APF 10

> 4 hours /shift: APF 10

Engineering and Work Practice Control Methods

Use grinder equipped with commercially available shroud and dust collection system.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

Dust collector must provide 25 cubic feet per minute (cfm) or greater of airflow per inch of wheel diameter and have a filter with 99% or greater efficiency and a cyclonic pre-separator or filter-cleaning mechanism.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: APF 10

> 4 hours /shift: APF 25

Engineering and Work Practice Control Methods

For tasks performed outdoors only:

Use grinder equipped with integrated water delivery system that continuously feeds water to the grinding surface.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

OR

Use grinder equipped with commercially available shroud and dust collection system.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

Dust collector must provide 25 cubic feet per minute (cfm) or greater of airflow per inch of wheel diameter and have a filter with 99% or greater efficiency and a cyclonic pre-separator or filter-cleaning mechanism.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

 

When Used Outdoors:

≤ 4 hours /shift: None

> 4 hours /shift: None

 

When used indoors or in an enclosed area:

≤ 4 hours /shift: None

> 4 hours /shift: APF 10

Engineering and Work Practice Control Methods

Use machine equipped with integrated water delivery system that continuously feeds water to the cutting surface.

Use machine equipped with dust collection system recommended by the manufacturer.

Dust collector must provide the air flow recommended by the manufacturer, or greater, and have a filter with 99% or greater efficiency and a filter-cleaning mechanism.

Operate and maintain tool in accordance with manufacturer’s instructions to minimize dust emissions.

When used indoors or in an enclosed area, use a HEPA-filtered vacuum to remove loose dust in between passes.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use a machine equipped with supplemental water sprays designed to suppress dust. Water must be combined with a surfactant.

Operate and maintain machine to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

For cuts of any depth on asphalt only:

Use machine equipped with exhaust ventilation on drum enclosure and supplemental water sprays designed to suppress dust.

Operate and maintain machine to minimize dust emissions.

For cuts of four inches in depth or less on any substrate:

Use machine equipped with exhaust ventilation on drum enclosure and supplemental water sprays designed to suppress dust.

Operate and maintain machine to minimize dust emissions.

OR

Use a machine equipped with supplemental water spray designed to suppress dust. Water must be combined with a surfactant.

Operate and maintain machine to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Use equipment designed to deliver water spray or mist for dust suppression at crusher and other points where dust is generated (e.g., hoppers, conveyers, sieves/sizing or vibrating components, and discharge points).

Operate and maintain machine in accordance with manufacturer’s instructions to minimize dust emissions.

Use a ventilated booth that provides fresh, climate-controlled air to the operator, or a remote control station.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Operate equipment from within an enclosed cab.

OR

When employees outside of the cab are engaged in the task, apply water and/or dust suppressants as necessary to minimize dust emissions.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Engineering and Work Practice Control Methods

Apply water and/or dust suppressants as necessary to minimize dust emissions.

OR

When the equipment operator is the only employee engaged in the task, operate equipment from within an enclosed cab.

 

Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

≤ 4 hours /shift: None

> 4 hours /shift: None

Privacy Preference Center